32011: Drive not responding to Write Request (is the drive in the network ?)

Info: Timeout [usec]
Data type: UDINT

Description:
CAN network:
To transfer a parameter value to the ACOPOS, the NC manager first sends a Write Request telegram from the PLC to the ACOPOS. This error is displayed if the NC manager did not receive the corresponding Read Response telegramm for a specific amount of time after the Write Request telegram was successfully transferred on the CAN bus.

POWERLINK network:
To transfer a parameter value to the ACOPOS, the NC manager first enters a Write Request telegram in the cyclic POWERLINK frame to the ACOPOS. This error is displayed if the corresponding Write Response telegram has not been entered in the cyclic POWERLINK frame from the ACOPOS after a specific amount of time.

Note:
The INFO is displayed from V1.142 on.

Reaction:
Resets the interface of the corresponding write channel.

Cause/Remedy:
Overload, malfunction or interruption of the network connection or ACOPOS failure.
See also error number 1004.